New Arrival China Measurement Of Radioactivity - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi Detail:
① The BIN (Background Identification of Normal) background ignores the technology
② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm
③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)
④ Nuclide recognition function (with sodium iodide probe / optional)
⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
Natural nuclide | 40K、226Ra、232Th |
Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
Special nuclear materials | 57Co、152Eu、238U |
⑥ High-speed sampling (fastest: 200ms)
project name | Parameter information |
Types of detectors | American EJ original imported plate plastic scintillator + Japan Hamamatsu low noise photomultiplier tube |
Detector volume | 5,10,15 optional with dual probe (door default dual probe) |
Maximum pass rate | 106cps |
energy range | 25keV~3MeV |
sensitivity | m5000cps / (Sv / h) (10 L, relative137Cs) |
Detection lower limit | Ability to detect radiation above the background of 5nSv / h |
Optional one, the neutron tube |
|
Optional dinnuclide recognition |
|
Misalarm rate
In a stable environment:
Use the space sensor, 10000 times, false alarm rate 1
Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h
γ Radiation Response
Occupup 50 times, alarm 49 times
outrange
Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves
Radiation-induced neutron alarm
No neutron alarm is triggered when the dose rate reaches 100 Sv / h
Background influence
When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
Natural nuclide | 40K、226Ra、232Th |
Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
Special nuclear materials | 57Co、152Eu、238U |
Note: Nuclide identification and neutron detection are optional, not in the standard system
Product detail pictures:
Related Product Guide:
Our eternal pursuits are the attitude of regard the market, regard the custom, regard the science as well as theory of quality the basic, have faith in the initial and administration the advanced for New Arrival China Measurement Of Radioactivity - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi, The product will supply to all over the world, such as: Cancun, Naples, Seychelles, Custom orders are acceptable with different quality grade and customer's especial design. We are looking forward to establish the good and successful cooperation in business with long terms from the customers of all over the world.
By Queena from Russia - 2017.02.18 15:54
Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
By Klemen Hrovat from Oman - 2018.06.19 10:42