① The BIN (Background Identification of Normal) background ignores the technology
② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm
③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)
④ Nuclide recognition function (with sodium iodide probe / optional)
⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
Natural nuclide | 40K、226Ra、232Th |
Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
Special nuclear materials | 57Co、152Eu、238U |
⑥ High-speed sampling (fastest: 200ms)
project name | Parameter information |
Types of detectors | Plate plastic scintillator + low noise photomultiplier tube |
Detector volume | 5,10,15 optional with dual probe (door default dual probe) |
Maximum pass rate | 106cps |
energy range | 25keV~3MeV |
sensitivity | m5000cps / (Sv / h) (10 L, relative137Cs) |
Detection lower limit | Ability to detect radiation above the background of 5nSv / h |
Optional one, the neutron tube |
|
Optional dinnuclide recognition |
|
1. Static detection efficiency (A-B)
A. Static detection efficiency of the pedestrian monitoring system
radioactive source | The main energykeV |
Static detection efficiency |
Dose rate at 1.5m / (nSv.h-1/MBq | |
s-1/MBq | s-1/(nSv.h-1) | |||
241Am | 60 | ≥220 | ≥94 | 2.3 |
57Co | 122,136 | ≥840 | ≥90 | 9.3 |
137Cs | 662 | ≥960 | ≥23 | 42 |
60Co | 1173,1332 | ≥1800 | ≥11 | 160 |
133Ba | 3,181,302,356 | ≥1680 | ≥73 | 23 |
pour:
1. The 252Cf neutron standard test source with a strong neutron source of 12000 / s (1 ± 20%) is placed at the location of the detector reference point
2. The neutron count rate shall meet the requirement of the count rate of> 100 (1 ± 20%) / s
Static detection efficiency of the B-row package monitoring system
radioactive source | The main energykeV |
Static detection efficiency |
Dose rate at 1.5m / (nSv.h-1/MBq | |
s-1/MBq | s-1/(nSv.h-1) | |||
241Am | 59.5 | ≥480 | ≥92 | 5.2 |
57Co | 122,136 | ≥2400 | ≥114 | 21 |
137Cs | 662 | ≥2640 | ≥28 | 95 |
60Co | 1173,1332 | ≥5760 | ≥16 | 360 |
133Ba | 3,181,302,356 | ≥4560 | ≥88 | 52 |
2. Detection sensitivity
Pedestrian monitoring system and line package monitoring system
Pedestrian: Detection probability f 90% speed v=1.2m/s
Line package: probe probability f 90% speed v=1m / s
radioactive source | Activity or quality |
137Cs | 0.08MBq |
60Co | 0.02MBq |
241Am | 2.27MBq |
3. Anti-interference performance of the neutron detector
When a 60Co source generates a dose rate at the geometric center of the neutron detector surface of the monitoring system, greater than 120 Sv / h, the monitoring system should not trigger a neutron alarm
4. False alarm rate: 0.01% (, neutron)
Probability of a detection system alarm caused by non-radioactive substances or non-SNM
5. overload characteristics
When the detector surface dose rate is> 120 Sv / h, the monitoring system shall maintain the alarm state and return to the background state, and the alarm release time is less than 60s.
6. Sensitivity consistency
Within the range of the detection area
Pedestrian ± 25% Line Pack ± 25%
Misalarm rate
In a stable environment:
Use the space sensor, 10000 times, false alarm rate 1
Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h
γ Radiation Response
Occup 50 times, alarm 49 times
Outrange
Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves
Radiation-induced neutron alarm
No neutron alarm is triggered when the dose rate of γ-ray reaches 100 Sv / h
Background influence
When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
Natural nuclide | 40K、226Ra、232Th |
Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
Special nuclear materials | 57Co、152Eu、238U |
Note: Nuclide identification and neutron detection are optional, not in the standard system